Series IP3000 incremental heavy duty shaft encoder up to 12 mm |
|
|
3 | X | K | 1 | - | 1 | 3 | X | X | - | X | X | X | X | ||||||||||
|
| |
Shaft Size |
| |
| |
Resolution - ppr |
||||||||||||||||||||
|
| |
12 x 25 mm |
| |
Exit |
|||||||||||||||||||||
|
| |
|
| |
A = Axial |
|||||||||||||||||||||
|
Housing Type |
| |
R = Radial |
||||||||||||||||||||||
|
D = Stainless Steel |
Connection |
|||||||||||||||||||||||
|
|
1 = 2m cable |
|||||||||||||||||||||||
|
2 = 5m cable |
||||||||||||||||||||||||
|
3 = 10 m cable |
||||||||||||||||||||||||
|
|
H = 9512 12 pin plug & socket |
|||||||||||||||||||||||
|
5...24 Volt Extended Line Driver is standard, optional Current Sink Open Collector is available
Zone 0, Class 1 Div 1 |
||||||||||||||||||||||||
| Technical Data | Connection Options | |||
| Operating temp: | - 20 ...+ 60 degrees C | Cable | ||
| - 4 ...+ 140 degrees F | PS GND | Black | ||
| On request: | -20 ... + 100 degrees C | PS 5 ... 24 V | Red | |
| Max frequency: | 150 kHz | Output A | White | |
| Current consumption: | 50 mA (max.) | Output B | Blue | |
| Power supply: | 5 - 24V | Output O | Yellow | |
| Weight: | 125 oz (3.5 kg) SS | Output A inv | Green | |
| Output B inv | Violet | |||
| Protection: | IP 66/X7 | Output O inv | Brown | |
| Housing: | Stainless Steel | |||
| Shaft: | Stainless Steel | Output | ||
| Bearings: | 2 x 6001 - (Z) (RS) | Diagram is shown with clockwise shaft rotation viewed from | ||
| Torque: | 0.7 oz/in (5 N-cm) | shaft end | ||
| Humidity: | Up to 98% permissible |
![]() |
||
| Speed: | 6000 RPM max. | |||
| Shock: | 10g (6msec) | |||
| Vibration: | 5g (500 Hz) | |||
| Shaft load: | Radial / Axial 10 N | |||
| Line driver output max: | 50 mA per channel | |||
| Max. ppr: | 5000 | |||
| Inertia: | 30 gm-cm2 | |||
| Certifications |
| To use the encoder in a hazardous area, a safety barrier or galvanic isolator has to be used. Our six channel barrier and isolator work with our encoders. Isolator Data Sheet |
| IP 66/X7 |
| ATEX [Certificate] |
| IECEx [Certificate] |
| CSA [Certificate] |
| GOST-CU [Certificate] |
| Mounting Instructions |
| Hook up the encoder
with the connections as described. Make sure power supply meets
specifications. Attach encoder to mounting bracket as shown.
Attach shaft using a flexible coupling.
|
| Dimensions |
|
|
| Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 |
| Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
| Wrexham LL13 8UG | E-mail: uksales@hohner.com |