Series 55 tachometer with 4 ... 20 mA output


5   5 X X - 0 5 X R - X X X X
 

Shaft Size

Connection

    

|____________|

10 = 10 mm 1 = 2m cable |
12 = 12 mm F = 9412 4-pin  |

16 = 16 mm

       plug & socket |
 

Speed

0300 = 300 rpm
1000 = 1000 rpm
3000 = 3000 rpm


 

Technical Data Connection Options
Operating temp: - 20 ...+   60 degrees C

9412

Cable

-   4 ...+ 140 degrees F

 + Loop

1 Red
Weight: 16 oz (0.45 kg)

 - Loop

2 Black
Protection: IP 64S, NEMA 3

Housing: Die Cast Zinc Alloy
Shaft: Aluminum
Bearings: 2 x 6805 ZZ
Torque: 0.4 oz/in (3 N-cm)
Humidity: Up to 98% permissible Output
Max Speed: 3000 RPM max.

Shaft load: Supports its own weight
 
 
 
 
 

Certifications

Best suited to work with the following isolators: (can be purchased from us as well)

Isolator Data Sheet [MTL5042] - DIN rail mounting - 131£

IP 64 S
SIRA Project Number 52 X 5980
II 1G EEx ia II C T4  and/or  I M1 EEx ia I
SIRA 00 ATEX 2085  [Certificate, Variations 1, 2, 3]  PDF file
UL E216028  [Certificate]  PDF file
  
Mounting Instructions

Mount fixture to the encoder with three self-tapping no. 8 screws and three no. 8 washers.  Slide the encoder onto the shaft.  With the setscrew, tighten the hollow shaft onto the shaft.  Mount the tether on the machine or motor-frame.  The tether can be bent to adapt to any surface.  This assembly allows the encoder to float and increases the lifetime of the bearings.  Connect the encoder as per wiring specifications.  Make sure power supply is within the proper voltage and current rating.  Encoder can be mounted with the setscrew on the machine side or on the opposite side for either CW or CCW.  See datasheet for CW and CCW directions of the outputs.

 

Technical data for tether:  0.3 mm stainless steel sheet

Dimensions


Hohner Automation Ltd. Tel: +44 (0) 1978 363-888
Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham LL13 8UG E-mail: uksales@hohner.com
United Kingdom Web: www.hohneronline.co.uk