Series 14 tachometer with 4 ... 20 mA output |
![]() |
1 | 4 | X | X | - | 0 | 5 | X | R | - | X | X | X | X | |||||||||||
|
Shaft Size |
Connection |
|
|__________| |
||||||||||||||||||||||
| 20 = 20 mm | 1 = 2m cable | | | |||||||||||||||||||||||
|
25 = 25 mm |
F = 9412 4-pin | | | |||||||||||||||||||||||
|
30 = 30 mm |
plug & socket | | | |||||||||||||||||||||||
| 35 = 35 mm |
Speed |
||||||||||||||||||||||||
|
40 = 40 mm |
0300 = 300 rpm | ||||||||||||||||||||||||
| 1000 = 1000 rpm | |||||||||||||||||||||||||
|
3000 = 3000 rpm |
|||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||
| Technical Data | Connection Options | ||||
| Operating temp: | - 20 ...+ 60 degrees C |
9412 |
Cable |
||
| - 4 ...+ 140 degrees F |
+ Loop |
1 | Red | ||
| Weight: | 39 oz (1.1 kg) |
- Loop |
2 | Black | |
| Protection: | IP 64S, NEMA 3 |
|
|||
| Housing: | Die Cast Zinc Alloy | ||||
| Shaft: | Aluminum | ||||
| Bearings: | 2 x 6805 ZZ | ||||
| Torque: | 0.4 oz/in (3 N-cm) | ||||
| Humidity: | Up to 98% permissible | Output | |||
| Max Speed: | 3000 RPM max. |
|
|||
| Shaft load: | Supports its own weight | ||||
| Certifications |
|
Best suited to work with the following isolators: (can be purchased from us as well) Isolator Data Sheet [MTL5042] - DIN rail mounting - 131£ |
| IP 64 S |
| SIRA Project Number 52 X 5980 |
| II 1G EEx ia II C T4 and/or I M1 EEx ia I |
| SIRA 00 ATEX 2085 [Certificate, Variations 1, 2, 3] PDF file |
| UL E216028 [Certificate] PDF file |
| Mounting Instructions |
|
Mount fixture to the
machine with three screws and three washers, M6 or 1/4". Slide the encoder
onto the shaft. With the setscrews, tighten the hollow shaft encoder onto
the shaft with a minimum clearance of 1/16" between fixture and encoder.
This assembly allows the shaft to float and increases the lifetime of the
bearings. Connect the encoder as per wiring specifications. Make sure
power supply is within the proper voltage and current rating. Encoder can
be mounted with the setscrew on the machine side or on the opposite side for
either CW or CCW. See datasheet for CW and CCW directions of the outputs.
Technical data for mount: 1/8" stainless steel wire
|
| Dimensions |
|
|
| Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 |
| Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
| Wrexham LL13 8UG | E-mail: uksales@hohner.com |
| United Kingdom | Web: www.hohneronline.co.uk |