Series CMMXE shaft encoder with 4...20mA output


M   X X X - 4 0 X X - X X X X
  |   |____|       |   |

    

Resolution

| | | | 0309 = 8 turns

| | | | 0408 = 16 turns
|

Shaft Size

| | 0507 = 32 turns
| K5 = 12 x 20 mm | | 0606 = 64 turns
| |

Exit

| | A = Axial
| | R = Radial

Protection

Connection
E = IP66/67 Stainless Steel 3 = 10 m cable
F = IP66/67 Aluminum 4 = 15 m cable


Please call +44 1978 363 888 in Europe or 1 800 295 5693 in North America or email us for pricing & delivery


Technical Data Connection Options
Operating temp: - 20 ...+   60 degrees C Cable
-   4 ...+ 140 degrees F PS GND Black
PS +24 Volts Red
Current consumption: 80 mA (max.) Output 4...20 mA White
Power supply: 24V
Weight: 1.5Kg to 2.5Kg Output
Housing: Aluminum or S. Steel Count will increment in CW direction.
Shaft: Stainless Steel
Bearings: 2 x 6001 RSH
Torque: 0.4 oz/in (3 N-cm)
Humidity: Up to 98% permissible
Speed: 3000 RPM max.
Shaft load: Radial / Axial 10 N

Certifications
Does not require a barrier for use in hazardous areas, it is EEx d IIC, making the barrier redundant.
IP 66/X8
EEx d II C:
SIRA 05ATEX1280
IECEX SIR 05.0059
 
Mounting Instructions
To mount encoder on machine:  Option 1 is to mount with three screws, option 2 is to use synchroflange mounting brackets.  Hook up the encoder with the connections as described.  Make sure power supply meets specifications.  Attach encoder to mounting bracket as shown.  Attach shaft using a flexible coupling.

Dimensions


Hohner Automation Ltd. Tel: +44 (0) 1978 363-888
Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham LL13 8UG E-mail: uksales@hohner.com