		 hohner  | 
		
		 Hohner Automation Ltd.  | 
	
| Home | Distributors | Terms | About Us | Accessories | Download 3D AutoCAD | 
| 
       Series NAMFPX incremental encoder with junction box connection and threaded and standard shafts for drawworks  | 
  
| 
	 
	 
 
	  | 
    
      
 
				 Zone 0, Class 1 Div 1  | 
  ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Technical Data | Connection Options | ||||
| Operating temp: | - 40 ...+ 100 degrees C | Terminals | |||
| - 40 ...+ 212 degrees F | + Loop A # 1 | 1 | |||
| Max frequency: | 150 kHz | - Loop A # 1 | 2 | ||
| Weight: | 53 oz (1.5 kg) | + Loop B # 1 | 3 | ||
| Protection: | IP 66M, NEMA 4 | - Loop B # 1 | 4 | ||
| Housing: | Aluminum | ||||
| Shaft: | Stainless Steel | ||||
| Bearings: | 2 x 6807 ZZ | ||||
| Torque: | 0.8 oz/in (6 N-cm) | ||||
| Shaft load: | Supports its own weight | ||||
| Humidity: | Up to 98% permissible | ||||
| Speed: | 3000 RPM | ||||
| Max. ppr | 5000 | ||||
| Shock: | 10g (6 msec) | ||||
| Vibration: | 5g (500 Hz) | ||||
| Output for NAMUR | |||||
| 
	   Diagram is shown clockwise  | 
    |||||
| Certifications | 
| Best suited to work with the following isolators: P+F KFD2 SOT2 EX2 | 
| IP 66M | 
| ATEX [Certificate] | 
| IECEx [Certificate] | 
| CSA [Certificate] | 
| GOST-CU [Certificate] | 
| Mounting Instructions | 
| Thread the encoder shaft onto the matching threaded shaft and tighten both ends. Add a bit of copper slip for it not to seize up. To keep encoder from rotating: have a pin to prevent rotation in one of the mounting holes, or a bracket bolted onto the mounting holes, or simply tie wrap the cable. Whatever is done, ensure there is a bit of play between encoder and mounting arrangement to prevent bearing damage. Hook up the encoder with the connections as described. Make sure power supply meets specifications. | 
| Dimensions | 
| 
       
		  | 
  
| Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 | 
| Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 | 
| Wrexham LL13 8UG | E-mail: uksales@hohner.com | 
| United Kingdom | Web: www.hohneronline.co.uk |