Series NAMFPX incremental hollow shaft encoder with 5...24V output |
|
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Please call +44 1978 363 888 in Europe or 1 800 295 5693 in North America or email us for pricing & delivery |
| Technical Data | Connection Options | ||||
| Operating temp: | - 20 ...+ 60 degrees C | Cable 2 meters | Connector | ||
| - 4 ...+ 140 degrees F | PS GND | Black | Any type of connector with more than 4 pins and an IP rating of 66 can be used, pin allocations will determined by end customer. More than one connector is possible as well. | ||
| Max frequency: | 5 kHz | PS 5...24 V | Red | ||
| Weight: | 53 oz (1.5 kg) | Output A | White | ||
| Protection: | IP 66M, NEMA 4 | Output B | Blue | ||
| Housing: | Aluminum | Output O | Yellow | ||
| Shaft: | Stainless Steel | Output A inv | Green | ||
| Bearings: | 2 x 6807 ZZ | Output B inv | Violet | ||
| Torque: | 0.8 oz/in (6 N-cm) | Output O inv | Brown | ||
| Shaft load: | Supports its own weight | ||||
| Humidity: | Up to 98% permissible | ||||
| Speed: | 3000 RPM | ||||
| Max. ppr | 5000 | ||||
| Output for Channels | |||||
|
Diagram is shown clockwise |
|
||||
| Certifications |
| To use the encoder in a hazardous area, a safety barrier or galvanic isolator has to be used. Our six channel barrier and isolator work with our encoders. Barrier Data Sheet Isolator Data Sheet |
| IP 66M |
| SIRA - 51D7236-1A |
| IM1 EEx (ia) I |
| II1G EEx (ia) IIB T4 [Certificate] PDF file |
| SIRA 02ATEX2317X [Certificate, P1, P2, P3] PDF file |
| UL E216028 [Certificate] PDF file |
| Mounting Instructions |
|
Slide encoder onto shaft. To keep encoder from rotating: have a pin to prevent rotation in one of the mounting holes, or a bracket bolted onto the mounting holes, or simply tie wrap the cable. Whatever is done, ensure there is a bit of play between encoder and mounting arrangement to prevent bearing damage. Hook up the encoder with the connections as described. Make sure power supply meets specifications.
|
| Dimensions |
|
|
| Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 |
| Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
| Wrexham LL13 8UG | E-mail: uksales@hohner.com |
| United Kingdom | Web: www.hohneronline.co.uk |