Series MXE stainless steel (EExd) shaft encoder up to 12 mm


M   X X X - 1 3 X X - X X X X
 

|

 

Shaft Size

|  

|

    

Resolution - ppr

| K5 = 12 x 20 mm | Exit
| | A = Axial

| | R = Radial
Protection

|

E = IP66/67 Stainless Steel Connection
F = IP66/67 Aluminum optional 3 = 10m cable
5 = 20m cable
  
5...24 Volt Extended Line Driver is standard, optional Current Sink Open Collector is available


Please call +44 1978 363 888 in Europe or 1 800 295 5693 in North America or email us for pricing & delivery


Technical Data Connection Options
Operating temp: - 20 ...+   60 degrees C Cable
-   4 ...+ 140 degrees F PS GND Black
PS 5 ... 24 V Orange
Max frequency: 150 kHz Output A White
Current consumption: 80 mA (max.) Output B Blue
Power supply: 5 - 24V Output O Yellow
Weight: 1.5Kg to 2.5Kg Output A inv Green
Protection: IP 66/67 Output B inv Violet
Housing: S. Steel or Aluminum Output O inv Brown
Shaft: S. Steel or Aluminum
Bearings: 2 x 6001 RSH Output
Torque: 0.7 oz/in (5 N-cm) Diagram is shown with clockwise shaft rotation viewed from 
Humidity: Up to 98% permissible

shaft end

Speed:  6000 RPM max.
Shock: 10g (6msec)
Vibration: 5g (500 Hz)
Shaft load: Radial / Axial 10 N
Line driver output max: 50 mA per channel
Max. ppr 5000
Inertia: 100 gm-cm2

Certifications
Does not require a barrier for use in hazardous areas, it is EEx d IIC, making the barrier redundant.
IP 66/X8
EEx d II C:
SIRA 05ATEX1280
IECEX SIR 05.0059
 
Mounting Instructions
Hook up the encoder with the connections as described.  Make sure power supply meets specifications.  Attach encoder to mounting bracket as shown.  Attach shaft using a flexible coupling.

Dimensions


Hohner Automation Ltd. Tel: +44 (0) 1978 363-888
Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham LL13 8UG E-mail: uksales@hohner.com