hohner |
Hohner Automation Ltd. |
Home | Distributors | Terms | About Us | Accessories | Download 3D AutoCAD |
Series E incremental shaft encoder up to 12 mm |
click for non intrinsically safe version
|
E | B | X | X | - | 1 | 3 | X | X | - | X | X | X | X | |||||||||||
|____| |
Shaft Size |
|
| |
| |
|
Resolution - ppr |
|||||||||||||||||||
| |
K2 = 6 x 10 mm |
| |
Exit |
||||||||||||||||||||||
| |
K4 = 10 x 20 mm |
| |
A = Axial |
||||||||||||||||||||||
| |
K5 = 12 x 20 mm |
| |
R = Radial |
||||||||||||||||||||||
| |
Connection |
||||||||||||||||||||||||
IP Rating |
1 = 2m cable |
||||||||||||||||||||||||
EA = IP54 |
2 = 5m cable |
||||||||||||||||||||||||
EB = IP65 (standard) |
G = 9418 8 pin plug & socket |
||||||||||||||||||||||||
H = 9512 12 pin plug & socket |
|||||||||||||||||||||||||
5...24 Volt Extended Line Driver is standard, optional Current Sink Open Collector is available
IECEx
Zone 0, Class 1 Div 1 |
Technical Data | Connection Options | ||||
Operating temp: | - 20 ...+ 60 degrees C | Cable | 12 pin | ||
- 4 ...+ 140 degrees F | PS GND | Black | 1 | ||
On request: | - 40 degrees | PS 5 ... 24 V | Red | 2 | |
Max frequency: | 150 kHz | Output A | White | 3 | |
Current consumption: | 50 mA (max.) | Output B | Blue | 4 | |
Power supply: | 5 - 24V | Output O | Yellow | 5 | |
Weight: | 21 oz (0.6 kg) | Output A inv | Green | 6 | |
Protection: | IP 65 (IP54 available) | Output B inv | Violet | 7 | |
Housing: | Aluminum | Output O inv | Brown | 8 | |
Shaft: | Stainless Steel | ||||
Bearings: | 2 x 6001 - (Z) (RS) | Output | |||
Torque: | 0.7 oz/in (5 N-cm) | Diagram is shown with clockwise shaft rotation viewed from | |||
Humidity: | Up to 98% permissible |
shaft end |
|||
Speed: | 6000 RPM max. | ||||
Shock: | 10g (6msec) | ||||
Vibration: | 5g (500 Hz) | ||||
Shaft load: | Radial / Axial 10 N | ||||
Line driver output max: | 50 mA per channel | ||||
Max. ppr | 5000 | ||||
Inertia: | 100 gm-cm2 |
Certifications | |
To use the encoder in a hazardous area, a safety barrier or galvanic isolator has to be used. Our six channel barrier and isolator work with our encoders. Isolator Data Sheet | |
IP 54 or 65 | |
ATEX [Certificate] | |
IECEx [Certificate] | |
CSA [Certificate] | |
GOST-CU [Certificate] | |
Mounting Instructions | |
Hook up the encoder with the connections as described. Make sure power supply meets specifications. Attach encoder to mounting bracket as shown. Attach shaft using a flexible coupling. | |
Dimensions | |
|
|
Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 |
Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
Wrexham LL13 8UG | E-mail: uksales@hohner.com |