Series 32 submersible incremental shaft encoder


3   2 1 2 - 0 1 X X - X X X X
  Shaft Size

Connection

    

Resolution - ppr

12 = 12 mm 03 = 2 m (6 ft) cable
  05 = 5 m (15 ft) cable
12 = 12 m (36 ft) cable
  68 = 68 m (200 ft) cable
 
Standard 5 - 24 Volts Extended Line Driver PS
Standard ABO & ABO inv output
 
Submersible to 5 bar
Burrgmann seal MG1 / 12-G6


Please call +44 1978 363 888 in Europe or 1 800 295 5693 in North America or email us for pricing & delivery


Technical Data Connection Options
Operating temp: + 00 ...+   60 degrees C Cable
+ 32 ...+ 140 degrees F PS GND Black
PS 5 ... 24 V Red
Line driver output: 50 mA / channel max Output A White
Current consumption: 80 mA (max.) Output B Blue
Power supply: 5 - 24V Output O Yellow
Weight:    70.5 oz (2.0 kg) Output A inv Green
Housing: Stainless Steel Output B inv Violet
Shaft: Stainless Steel Output O inv Brown
Bearings: 2 x 6001 ZZ
Torque: 0.4 oz/in (3 N-cm) Output
Humidity: Up to 98% permissible A is 90 degrees before B in clockwise direction 
Speed: 3000 RPM max.
Shaft load: Radial / Axial 10 N
Max ppr: 5000 ppr
Pressure: Series 32 2.5 bar - IP 66 / 68
 
 

Certifications
To use the encoder is a hazardous area, a safety barrier has to be used.  Our six channel barrier series AB was designed to work with our encoders.  Data Sheet
IP 66M / X8  [Certificate PDF File
SIRA - 51D9535-A
IM1  EEx (ia) I
II1G  EEx (ia) IIB T4  [Certificate]  PDF file
SIRA 02ATEX2317X
UL E216028  [Certificate]  PDF file
 
Mounting Instructions
To mount encoder on machine:  Option 1 is to mount with three screws, option 2 is to use synchroflange mounting brackets.  Hook up the encoder with the connections as described.  Make sure power supply meets specifications.  Attach encoder to mounting bracket as shown.  Attach shaft using a flexible coupling.

Dimensions


Hohner Automation Ltd. Tel: +44 (0) 1978 363-888
Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham LL13 8UG E-mail: uksales@hohner.com
United Kingdom Web: www.hohneronline.co.uk

Hit Counter