Series 07x incremental plastic encoder up to 12mm


(hollow shaft shown)

0

 

7

 

X

 

X - 1   3   1

 

R - X   X   X   X
Shaft Size     |   Resolution
10 = 10 mm   Connection  
12 = 12 mm   1 = 9 pin D with 2 m  
K4 = 10x20 solid   of cable attached  
K5 = 12x20 solid      

    IECEx

Zone 0, Class 1 Div 1


Technical Data Connection Options
Operating temp: - 20 ...+   60 degrees C 9 pin D
-   4 ...+ 140 degrees F PS GND 1 Output O 5
Power Supply: 5...24 Volts PS 5 ... 24 V 2 Output A inv 6
Max frequency: 150 kHz Output A 3 Output B inv 7
Weight: 3.6 oz (110 g) Output B 4 Output O inv 8
Protection: IP 54
Housing: ABS Plastic Output
Shaft: Aluminum
Bearings: 2 x 6803 Z
Torque: 0.7 oz/in (5 N-cm)
Shaft load: Supports its own weight
Humidity: Up to 98% permissible
Speed:  2000 RPM max.
Max. ppr 1024 ppr
 

Certifications
To use the encoder in a hazardous area, a safety barrier or galvanic isolator has to be used.  Our six channel barrier and isolator work with our encoders.  Isolator Data Sheet
IP 54
ATEX  [Certificate]
IECEx  [Certificate]
CSA [Certificate]
GOST-CU [Certificate]
 
Mounting Instructions

Mount the tether on the machine or motor-frame.  The tether can be bent to adapt to any surface.  This assembly allows the encoder to float and increases the lifetime of the bearings.  Connect the encoder as per wiring specifications.  Make sure power supply is within the proper voltage and current rating.  Encoder can be mounted with the setscrew on the machine side or on the opposite side for either CW or CCW.  See datasheet for CW and CCW directions of the outputs.

 

Technical data for tether:  0.3 mm stainless steel sheet


Dimensions


Hohner Automation Ltd. Tel: +44 (0) 1978 363-888
Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham LL13 8UG E-mail: uksales@hohner.com
United Kingdom Web: www.hohneronline.co.uk