Series H incremental shaft encoder up to 12 mm (Ex ia IIB, IECEx certified)


H   X X X - 1 3 X X - X X X X - C
|____|

Shaft Size

| | Resolution - ppr
| K2 = 6 x 10 mm | Exit
| K4 = 10 x 20 mm | A = Axial
| K5 = 12 x 20 mm | R = Radial
| Connection

IP Rating

1 = 2m cable

HA = IP54

2 = 5m cable

HB = IP65 (standard)

H - 9512 12 pin plug & socket
 
Ex ia IIB T4 and Ex ia I (IECEx SIR 06.0060)
 

Price: From 190£


Technical Data Connection Options
Operating temp: - 20 ...+   60 degrees C Cable 12 pin
-   4 ...+ 140 degrees F PS GND Black 1
On request: - 40 degrees PS 5 ... 24 V Red 2
Max frequency: 150 kHz Output A White 3
Current consumption: 50 mA (max.) Output B Blue 4
Power supply: 5 - 24V Output O Yellow 5
Weight:    21 oz (0.6 kg) Output A inv Green 6
Protection: IP 65 (IP54 available) Output B inv Violet 7
Housing: Aluminum Output O inv Brown 8
Shaft: Stainless Steel
Bearings: 2 x 6001 - (Z) (RS) Output
Torque: 0.7 oz/in (5 N-cm) Diagram is shown with clockwise shaft rotation viewed from 
Humidity: Up to 98% permissible

shaft end

Speed:  6000 RPM max.
Shock: 10g (6msec)
Vibration: 5g (500 Hz)
Shaft load: Radial / Axial 10 N
Line driver output max: 50 mA per channel
Max. ppr 5000
Inertia: 30 gm-cm2

Certifications
To use the encoder in a hazardous area, a safety barrier has to be used.  Our six channel barrier series AB was designed to work with our encoders.  Data Sheet
IP 54 or 65
Ex ia IIB T4 and Ex ia I (IECEx SIR 06.0060)
 
Mounting Instructions
Hook up the encoder with the connections as described.  Make sure power supply meets specifications.  Attach encoder to mounting bracket as shown.  Attach shaft using a flexible coupling.
Dimensions


Hohner Automation Ltd. Tel: +44 (0) 1978 363-888
Whitegate Industrial Estate Fax: +44 (0) 1978 364-586
Wrexham LL13 8UG E-mail: uksales@hohner.com