hohner |
Hohner Automation Ltd. |
| Home | Distributors | Terms | About Us | Accessories | Download 3D AutoCAD |
|
Series CMMXE ProfiBus multiturn absolute stainless steel shaft encoder |
|
|
M | U | K | 5 | - | 7 | M | T | X | - | 1 | 2 | 1 | 2 | |||||||||||
|
| |
Shaft Size |
| |
|
Resolution |
|||||||||||||||||||||
| | | K5 = 12 x 20 mm |
| |
12 x 12 bits |
||||||||||||||||||||||
| | | Exits | ||||||||||||||||||||||||
| | | 3 = 3 glands | ||||||||||||||||||||||||
| Protection | 2 = 2 glands, 1 bung | ||||||||||||||||||||||||
| U = IP66/67 Stainless Steel | 1 = 1 gland, 2 bungs | ||||||||||||||||||||||||
|
Standard ProfiBus-DP output with three cable glands and back end to be field opened as standard ProfiBus encoders
|
|||||||||||||||||||||||||
|
Class I, Zone 1; Zone 21; Class II, Div 2 |
|||||||||||||||||||||||||
| Technical Data | Communication Data | |||
| Operating temp: | - 40 ...+ 60 degrees C | Interface: | RS485 | |
| - 40 ...+ 140 degrees F | Protocol: | ProfiBus DP Class 2 Profile C2 | ||
| Current consumption: | 230 mA | (programmable) | ||
| Power supply: | 10 - 30 V | Resolution: | Singleturn max 16 bit | |
| Weight: | 4.0 Kg | Multiturn 30 bit (16s x 14m bit) | ||
| Protection: | IP 66/67 | Linearity: | +/- 2 LSB x 16 bit | |
| Housing: | Stainless Steel | +/- 1 LSB x 14 bit | ||
| Shaft: | Stainless Steel | +/- 1/2 LSB x 12 bit | ||
| Bearings: | 2 x 6001 | Type of Code: | Binary | |
| Torque: | 0.7 oz/in (5 N-cm) | Device Address: | Set via dip switches | |
| Humidity: | Up to 98% permissible | Active Bus | ||
| Speed: | 6000 rpm | Term Resistors: | Set via dip switches | |
| Shock: | 10g (6msec) | Programmable Functions | ||
| Vibration: | 5g (500 Hz) | Direction | ||
| Shaft load: | Radial / Axial 10 N | Resolution per revolution | ||
| Inertia: | 100 gm-cm2 | Total resolution | ||
| Preset | ||||
| Data Sheet for ProfiBus | Speed | |||
| Link to data sheet | PSM332LP/12/12 | Acceleration | ||
| Certifications |
| Does not require a barrier for use in hazardous areas, it is Flameproof, making the barrier redundant. |
| IP 66/X8 |
| Ex d IIC |
| ATEX [Certificate] |
| IECEx [Certificate] |
| GOST-CU [Certificate] |
| Mounting Instructions |
| Hook up
the encoder with the connections as described. Make sure power
supply meets specifications. Attach encoder to mounting bracket as
shown. Attach shaft using a flexible coupling.
|
| Dimensions |
|
|
| Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 |
| Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
| Wrexham LL13 8UG | E-mail: uksales@hohner.com |
| United Kingdom | Web: www.hohneronline.co.uk |