hohner |
Hohner Automation Ltd. |
| Home | Distributors | Terms | About Us | Accessories | Download 3D AutoCAD |
|
Series CMMXE stainless steel absolute parallel multiturn shaft encoder |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Technical Data | Connection Options | |||
| Operating temp: | - 20 ...+ 60 degrees C | Bin / Gray | cable | |
| - 4 ...+ 140 degrees F | PS GND | Black | ||
| On request: | -20 ... + 100 degrees C | PS 12 ... 24 V | Red | |
| Power supply: | 11 - 24V | 2-0 (LSB) | White | |
| Current consumption: | 100 mA (max.) | 2-1 | Blue | |
| Line driver output max: | 50 mA per channel | 2-2 | Yellow | |
| Weight: | 2.5 kg | 2-3 | Green | |
| 2-4 | Violet | |||
| Protection: | IP 66 / 67 | 2-5 | Brown | |
| Housing: | Stainless Steel | 2-6 | Pink | |
| Shaft: | Stainless Steel | 2-7 | Grey | |
| Bearings: | 2 x 6001 ZZ C2 | 2-8 | White/Black | |
| Torque: | 0.4 oz/in (3 N-cm) | 2-9 | Red/Blue | |
| Shaft Seal: | Nitrile Double Lip | 2-10 | Red/Brown | |
| Humidity: | Up to 98% permissible | 2-11 (MSB) | Green/Blue | |
| Speed: | 300 RPM max. | Multiturn Section | ||
| Shock: | 10g (6msec) | 2-12 | Yellow/White | |
| Vibration: | 5g (500 Hz) | 2-13 | White/Red | |
| Shaft load: | Radial max 10 lbs | 2-14 | Yellow/Blue | |
| 2-15 | White/Blue | |||
| 2-16 | Blue/Brown | |||
| 2-17 | Black/Brown | |||
| 2-18 | White/Green | |||
| 2-19 | Brown/Green | |||
| 2-20 | Green/Grey | |||
| 2-21 | Yellow/Grey | |||
| 2-22 | Grey/Brown | |||
| 2-23 | White/Grey | |||
|
ccw/cw |
Yellow/Brown (put to ground for dir change) |
|||
| Count
will increment in cw direction **colours may vary due to cable supplier - please verify with label on unit or contact us if in doubt
|
|
|
|
| Certifications |
| Flameproof, does not require barrier for use in hazardous areas, and we use a barrier gland for added safety |
| IP 66/X7 |
| ATEX [Certificate] |
| IECEx [Certificate] |
| CSA [Certificate] |
| GOST-CU [Certificate] |
| Mounting Instructions |
| To mount
encoder on machine: Option 1 is to mount with 3 screws or, option 2
is to mount using synchroflange mounting brackets. Hook up the
encoder with the connections as described. Make sure power supply
meets specifications. Attach encoder to mounting bracket as
shown. Attach shaft using a flexible coupling.
|
| Dimensions (radial only) |
|
|
| Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 |
| Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
| Wrexham LL13 8UG | E-mail: uksales@hohner.com |