hohner |
Hohner Automation Ltd. |
| Home | Distributors | Terms | About Us | Accessories | Download 3D AutoCAD |
|
Series 32 submersible absolute parallel shaft encoder |
![]() Do not run the encoder when not submersed, as this will damage the seal. Only use this encoder for applications that require full submersion, 100% of the time. |
3 | 2 | 1 | 2 | - | 2 | 0 | X | X | - | 0 | 0 | 1 | 2 | |||||||||||
| Shaft Size |
|
| | | |
|
Resolution |
||||||||||||||||||||
| 12 = 12 mm | | | | | 12 = 12 bits | ||||||||||||||||||||||
|
Connection |
| | ||||||||||||||||||||||||
| 2 = 2 m (6 ft) cable | Output Code | ||||||||||||||||||||||||
| 5 = 5 m (15 ft) cable | 0 = gray cw | ||||||||||||||||||||||||
| B = 12 m (36 ft) cable | 4 = binary cw | ||||||||||||||||||||||||
|
Z = 68 m (200 ft) cable |
|||||||||||||||||||||||||
|
Submersible to 2.5 bar |
|||||||||||||||||||||||||
|
Burrgmann seal MG1 / 12-G6 |
|||||||||||||||||||||||||
| Longer cable is available upon request | |||||||||||||||||||||||||
| Technical Data | Connection Options | |||
| Operating temp: | + 00 ...+ 60 degrees C | cable with numbers | ||
| + 32 ...+ 140 degrees F | PS GND | 1 | ||
| PS + 12 ... 24 V | 2 | |||
| Seal: | Burrgmann: | Channel 2-0 | 3 | |
| MG1 / 12-G6 | Channel 2-1 | 4 | ||
| Power supply: | 11 ... 24V | Channel 2-2 | 5 | |
| Weight: | 70.5 oz (2.0 kg) | Channel 2-3 | 6 | |
| Housing: | Stainless Steel | Channel 2-4 | 7 | |
| Shaft: | Stainless Steel | Channel 2-5 | 8 | |
| Bearings: | 2 x 6001 ZZ | Channel 2-6 | 9 | |
| Torque: | 0.4 oz/in (3 N-cm) | Channel 2-7 | 10 | |
| Humidity: | Up to 98% permissible | Channel 2-8 | 11 | |
| Speed: | 500 RPM max. | Channel 2-9 | 12 | |
| Shaft load: | Radial / Axial 10 N | Channel 2-10 | 13 | |
| Pressure: Series 32 | 2.5 bar - IP 66 / 68 | Channel 2-11 | 14 | |
| Output |
| Count will increment in CW direction. |
![]()
|
| Certifications |
| IP 66M / X8 [Certificate] PDF File |
| Mounting Instructions |
| To mount
encoder on machine: Option 1 is to mount with three screws, option 2
is to use synchroflange mounting brackets. Hook up the encoder with the connections as described. Make sure
power supply meets specifications. Attach encoder to mounting
bracket as shown. Attach shaft using a flexible coupling.
|
| Dimensions |
|
|
| Hohner Automation Ltd. | Tel: +44 (0) 1978 363-888 |
| Whitegate Industrial Estate | Fax: +44 (0) 1978 364-586 |
| Wrexham LL13 8UG | E-mail: uksales@hohner.com |