hohner

    Hohner Corporation


Home Email Distributors Terms About Us Accessories Download 3D AutoCAD

Series 88 Absolute DeviceNet Encoder


8   8   X   X - 3   3   X   X - A   0   1   2
  |___|   |  

|

 
  |

IP rating

  Connection
Shaft Size 0 = IP54   0 = DeviceNet Cable

07 = 1" with 1/4" keyway

  4 = 5 pin micro
17 = 30 mm
03 = 1/2"
16 = 24 mm
25 = 1 - 1/4"
05 = 5/8" with 3/16" keyway

   


Technical Data Encoder Description
Operating temp: - 20 ...+   60 degree C The 12 bit absolute encoder has a 12 bit binary value
- 04 ...+ 140 degree F
On request - 20 .. +100 degree C
Current consumption: 80 mA (max.)
6 ft drop cable Device Configuration
Weight:    38.5oz (1.1 kg) ODVA profile: Resolver
Protection: IP 54 Explicit Peer to Peer Messaging Not supported
Housing: Die Cast Zinc Alloy I / O Peer to Peer Messaging Not supported
Shaft: Aluminum Configuration consistency value Not supported
Bearings: 2 x 6008 ZZ C2 Faulted node recovery Not supported
Torque: 0.4 oz/in (3 N-cm) Baud rate Supported
Humidity: Up to 98% permissible Master / Scanner Not supported
Speed:  3000 RPM max. I / O Slave messaging Not supported
Directions Numbers rising in cw direction Bit strobe Not supported
Poll  Supported
Standards Cyclic Not supported
UL file number  -  198887 Change of state Not supported
European standard EN 50324 EDS
Tested by University of Michigan Vendor ID 34
Devicetype  9
Product code 1
Product name MTDR
Catalog 12 bit absolute encoder
Expected response data 4 bytes
Maximum value 12 bit

Mounting Instructions
Mount fixture to the machine with three screws and three washers, M6 or 1/4".  Slide the encoder onto the shaft.  With the setscrews, tighten the hollow shaft encoder onto the shaft with a minimum clearance of 1/16" between fixture and encoder.  This assembly allows the shaft to float and increases the lifetime of the bearings.
Connect the encoder as per wiring specifications. Make sure power supply is within the proper voltage and current rating.  Encoder can be mounted with the setscrew on the machine side or on the opposite side for either CW or CCW.  See datasheet for CW and CCW directions of the outputs.

Technical data for mount:  1/8" stainless steel wire

Dimensions

 


Hohner Corp. Tel: (905) 563 4924
5536 Regional Road 81 Fax: (905) 563 7209
Beamsville, Ontario E-mail: hohner@hohner.com