hohner |
Hohner Corporation |
Home | Distributors | Terms | About Us | Accessories | Download 3D AutoCAD |
Series 03 multiturn XML RS232 encoder |
![]() |
|
Technical Data | XML Data | |||
Operating temp: | - 20 ...+ 60 degrees C | Max bit: | 9 + 9 bit multiturn | |
- 4 ...+ 140 degrees F | Power supply: | From PC RS232 | ||
Max frequency: | 20 kHz | Max frequency: | 20 kHz | |
Power: | Powered from PC | |||
Connection: | 9 pole D connector | Connection: | ||
Weight: | 20 oz (0.6 kg) | 6 ft cable with 9 pole D female adaptor | ||
Protection: | IP 55 | 1 = NC | ||
Housing: | Stainless Steel | 2 = Rx | ||
Shaft: | Stainless Steel | 3 = Tx | ||
Bearings: | 3 x 6001 zz | 4 = DTR (+ 5V from USB converter or external supply) | ||
Torque: | 0.4 oz/in (3 N-cm) | 5 = GND | ||
Humidity: | Up to 98% permissible | 6 = NC | ||
Speed: | 3000 RPM max. | 7 = RTS | ||
Shock: | 10g (6msec) | 8 = CST | ||
Vibration: | 5g (500 Hz) | 9 = NC | ||
Shaft load: | Supports its own weight |
User Instructions |
1. Connect directly to PC HyperTerminal with the following settings: 9600 bd / 8 bit / no parity / 1 stop / ASCII 2. For long cable distances, use an RS485 isolated repeater. 3. For access in Networks, connect to a "serial to Ethernet" converter 4. For access in Wireless networks, connect to a "serial to wireless" converter 5. To use with a USB port, use the Hohner part number 5002 converter
Any professional program like WinWdege, WonderWare and Labview can be used with the hyper-terminal for further processing. For specific software adoptions in XML systems, please contact us
We can offer customized menus for our software, making it task specific for your applications:
Multiturn 9 + 9 bit When connected – continuous output of position. Max count = 18 bit (262144 counts)
|
Mounting Instructions |
Slide encoder onto shaft. Use torque arm to prevent rotation. Hook up the encoder with the connections as described. Make sure power supply meets specifications. |
Dimensions |
|
Hohner Corp. | Tel: (905) 563 4924 |
5536 Regional Road 81 | Fax: (905) 563 7209 |
Beamsville, Ontario | E-mail: hohner@hohner.com |
Canada L0R 1B3 | Web: www.encoderonline.com |